CN Cable Group Co., Ltd.

Scientific, Rigorous, Systematic Integrity, Efficiency, Responsible Open, Communicative, Enthusiasm

Manufacturer from China
Active Member
7 Years
Home / Products / Special Cables /

Outdoor / Indoor Two Cores Telephone Drop Wire With PVC / HDPE Insulation

Contact Now
CN Cable Group Co., Ltd.
City:zhengzhou
Province/State:henan
Country/Region:china
Contact Person:MissAndrea
Contact Now

Outdoor / Indoor Two Cores Telephone Drop Wire With PVC / HDPE Insulation

Ask Latest Price
Video Channel
Brand Name :CN CABLE
Model Number :DROP WIRE
Certification :CE
Place of Origin :HENAN
MOQ :10000meters
Payment Terms :L/C, T/T
Supply Ability :1000000meters per month
Delivery Time :20days after payment
Packaging Details :roll, wooden drum or request
conductor :copper/tinned copper,CCS, CCA
insulation :PVC/HDPE
name :telephone drop wire
type :Special Cables
certification :CE
application :Outdoor / Indoor
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Use for Outdoor/indoor two cores flat 8 configuration telephone drop wire

Application:

Drop cable is for connecting power amplifier and broadcasting systems, transmitting the audio signals amplified by the amplifier

Construction:

1: conductor : 0. 5mm, 0. 6mm, 0. 8mm or 0. 9mm bare/ tinned copper wire request

2: insulation: HDPE, PVC or request

3. The assembly should be consisting of two conductor lay parallel insulated to form a figure 8 configuration. It should be possible to separate the drop wire into two fully insulated conductors by cutting along the interconnecting web.

4. Polarity identification should be provide by a single ridge tracer longitudinally molded along the jacket throughout the intere length the drop wire unaided eye and to the touch.

Outdoor / Indoor Two Cores Telephone Drop Wire With PVC / HDPE Insulation

Outdoor / Indoor Two Cores Telephone Drop Wire With PVC / HDPE InsulationOutdoor / Indoor Two Cores Telephone Drop Wire With PVC / HDPE Insulation

Outdoor / Indoor Two Cores Telephone Drop Wire With PVC / HDPE Insulation

Data sheet

Number of core Minimum insulation thickness Maximum cable dimension diameter * height Nominal weight

mm

mm

kg/km

0.71mm conductor ,2.75mm insulated wire

2

1.02

2.75*6.0

20

0.81mm conductor ,2.41mm insulated wire

2

0.8

2.5*5.4

23

0.91mm conductor ,2.41mm insulated wire

2

0.75

2.7*5.6

25

1.14mm conductor ,4.18mm insulated wire

2

1.52

4.44*9.4

34

Electrical requirements and tests:

Sparkling: Voltage application during the manufacturing process (after the extrusion) in order to detect pores or other insulation failures
Minimum insulation resistance at 15.6 ºC:
- Between conductors: 92 Mohm/km (500 VCC power must be applied during 1 minute. This test must be realized dry. )
Minimum dielectric breakdown strength at VCC:
- between both conductors: The insulation must resist during 3 minutes a continuous voltage of 7500 VCC. This test must be realized dry)
Mutual capacity: 64 - 79 nF/km at 1 KHz
Characteristic impedance: 124 ± 20 Ohms

Maximum Individual Maximum Average
1 KHz 1.3 dB/km 0.95 dB/km
150 KHz 5.2 dB/km 4.70 dB/km
772KHz 18.0 dB/KM 15.00 dB/km

Inquiry Cart 0